corrosense measures corrosion rate by evaluating the electrochemical response of a reference metal surface. This evaluation indicates the corrosion rate at the exact moment of the measurement, providing you with direct insight on how the piping system changes over time.
| Tekniska data | |
| Measuring principle | LPR & EIS |
| Measuring range | 0 ... 5 mm/a |
| Pressure range | 0 ... 6 bar |
| Temperature range | 0 ... 60 °C |
| Accuracy | ± 3% FS |
| Resolution | 0,0001 |
| Calibration method | Laboratory comparison |
Electrical data | |
| Power supply | 12 VDC, 24 VDC |
| Electrical connection | Pin type |
| Output signal | Rs485, 4 ... 20 mA |
| Protection grade | IP68 |
| Cable length | 5 m or custom (per request) |
Materials | |
| Probe | Carbon steel, copper, stainless steel |
| Pipe thread | G1 |
| Shell | Stainless steel |